Hi beth do not add a vapor barrier on top of the insulation in your attic since the paper facing on the existing insulation is the vapor barrier.
No vapor barrier in attic.
With spray foam unlike with loose fill or batts you must cover the soffit vents they aren t needed to keep the roof cool.
Not every wall does.
Vapor barrier vb insulation batt with paper facing should not be placed over any existing insulation creating a trap.
Then cover the foam with drywall as required for fire safety.
The paper facing contains a layer of impermeable asphalt that prevents water vapor from passing through it.
Meanwhile air leakage through a 1 square inch hole in a sheet of drywall allows 30 quarts of water vapor to pass through the drywall under the same conditions.
Foam blocks airflow needs no vapor barrier and has a higher r value per inch than loose fill or batts so you ll get more protection with less depth.
A third of a quart versus 30 quarts.
Note that a poor effort at establishing a vapor barrier may be worse than no effort at all.
Improperly installed a vapor barrier may actually trap moisture inside a wall while a wall that is more porous can breathe effectively and be.
After the insulation is in place you will want to add a vapor retarder sometimes called a vapor barrier if you need one.
The insulation fiberglass or cellulose is then placed on top of the drywall with no vapor barrier above or below.
The goal of vapor barrier strategies is to prevent moisture from collecting and corrupting building materials.
If your climate does not meet these conditions a vapor retarder like latex ceiling paint will work well for your house if you are in all other climates except the hot dry and hot humid.
On the other hand an air barrier a properly detailed air tight drywall ceiling for example in the absence of a vapor barrier can be effective since it stops the flow of vapor laden air.
The permeance of unpainted drywall is very high generally between 20 and 90 so it s not a vapor retarder at all.
A plastic vapor barrier is best installed in a vented attic within climates with over 8 000 heating degree days.
Do not use poly for a vapor barrier.
The assembly must be able to dry in either direction should condensation occur.
If used the vb is placed against the heated side in winter.